Right Angle National Pipe Thread (NPT) Liquid-Tight Cordgrips
Strain Reliefs for Wires & Cables
Right Angle NPT Liquid-Tight Cordgrips provide Liquid-Tight integrity, even in the open position. They are all-nylon construction with a TPE gland, molded in the open position for ease of installation, and come in 3 sizes to fit cable, tubing, etc., with diameters of 0.065in - 0.450in (1.70mm-11.40mm).
Unit of Measure
Items |
20300307-A030 0.069 Inch (in) Minimum Cable Size Right Angle National Pipe Thread (NPT) Liquid-Tight Black Cordgrip |
20300307-A070 0.069 Inch (in) Minimum Cable Size Right Angle National Pipe Thread (NPT) Liquid-Tight Gray Cordgrip |
20300308-A030 0.181 Inch (in) Minimum Cable Size Right Angle National Pipe Thread (NPT) Liquid-Tight Black Cordgrip |
20300308-A070 0.181 Inch (in) Minimum Cable Size Right Angle National Pipe Thread (NPT) Liquid-Tight Gray Cordgrip |
20300309-A030 0.170 Inch (in) Minimum Cable Size Right Angle National Pipe Thread (NPT) Liquid-Tight Black Cordgrip |
|||||
Description | N/A Right Angle NPT Liquid-Tight Cordgrips provide Liquid-Tight integrity, even in the open position. They are all-nylon construction with a TPE gland, molded in the open position for ease of installation, and come in 3 sizes to fit cable, tubing, etc., with diameters of 0.065in - 0.450in (1.70mm-11.40mm). | |||||||||
Type | N/A Cord | |||||||||
Angle | N/A 90 º | |||||||||
Material | N/A Nylon 6/6 with Thermoplastic Elastomers (TPE) Gland | |||||||||
Color | N/A Black | N/A Gray | N/A Black | N/A Gray | N/A Black | |||||
Temperature Rating | N/A -22 to 212 ºF30 to 100 ºC | |||||||||
Wrench Flats | N/A 0.750 in19.10 mm | N/A 0.750 in19.10 mm | N/A 0.750 in19.10 mm | N/A 0.750 in19.10 mm | N/A 0.950 in24.10 mm | |||||
Hub Type | N/A National Pipe Thread (NPT) | |||||||||
Maximum Cable Size | N/A 0.187 in4.70 mm | N/A 0.187 in4.70 mm | N/A 0.305 in7.70 mm | N/A 0.305 in7.70 mm | N/A 0.450 in11.40 mm | |||||
Clearance Hole Size | N/A 0.670 in17.00 mm | N/A 0.670 in17.00 mm | N/A 0.670 in17.00 mm | N/A 0.670 in17.00 mm | N/A 0.875 in22.20 mm | |||||
Minimum Cable Size | N/A 0.069 in1.80 mm | N/A 0.069 in1.80 mm | N/A 0.181 in4.60 mm | N/A 0.181 in4.60 mm | N/A 0.170 in4.30 mm | |||||
Maximum Closed Overall Length | N/A 1.960 in49.80 mm | N/A 1.960 in49.80 mm | N/A 1.960 in49.80 mm | N/A 1.960 in49.80 mm | N/A 2.400 in61.00 mm | |||||
Right Angle Height | N/A 0.880 in22.30 mm | N/A 0.880 in22.30 mm | N/A 0.880 in22.30 mm | N/A 0.880 in22.30 mm | N/A 1.060 in26.90 mm | |||||
Sealing Nut Length | N/A 1.070 in27.10 mm | N/A 1.070 in27.10 mm | N/A 1.070 in27.10 mm | N/A 1.070 in27.10 mm | N/A 1.380 in35.10 mm | |||||
Threaded Length | N/A 0.530 in13.50 mm | N/A 0.530 in13.50 mm | N/A 0.530 in13.50 mm | N/A 0.530 in13.50 mm | N/A 0.620 in15.70 mm | |||||
Weight | N/A | N/A 6 lb | N/A | N/A | N/A | |||||
Flammability Rating | N/A 94V-2 | |||||||||
Ingress Protection (IP) Rating | N/A Ingress Protection (IP) 68 per DIN 40050 up to 70 psi (5 bar) Water Pressure | |||||||||
Industry Standards/Certifications | N/A Listed under Underwriter's Laboratories File #E-51579. Certified by the Canadian Standards Association File #93876C. | |||||||||
Features and Benefits |
N/A
|
|||||||||